Instrumentation insulation

Instrumentation insulation Instrumentation has been widely used in the industry, and it has the function of insulation and protection for instrumentation. Many people know that instrumentation has the function of heat preservation and protection, so what is the temperature value? What heat insulation measures are there?

In general, the temperature of the medium in the instrument pipeline should be between 20 and 80 degrees, and the temperature in the instrument incubator should be maintained between 15 and 20 degrees. In order to compensate for the heat emitted and lost by the instrument pipelines and containers and instrument incubators, insulation heat tracing measures must be taken.

At present, there are mainly two kinds of heat-retaining heat tracing measures, one is traditional steam and hot water heat tracing. The other is electric heat tracing. In recent years, with the maturation of electric heat tracing technology and its unique advantages, it will gradually become a new generation of heat preservation methods that replace steam and hot water heating. The steam heating of the instrument incubator is mainly composed of a box body, a lined insulation material, a transmitter bracket, and a U-shaped steam radiator. In order to facilitate the daily maintenance, the observation window is often provided on the door of the box, and the box top may be provided with an opening for inserting bimetal without temperature.

The electric heating of the instrument heat preservation box generally adopts the electric heating tube, while the electric heat tracing of the instrument pipeline adopts the electric heating belt. The electric heating tube is the outer shell of the seamless steel tube, and the resistance wire is filled in and filled with the magnesium oxide powder insulation. The electric heat tracing has heat. The high suburban rate, energy saving, simple design, convenient construction and installation, no pollution, long service life, and the advantages of remote control and automatic control. It is the technological development direction to replace steam and hot water heating. It has been widely used in industrial and mining enterprises in various industries.

Through the analysis of the instrument world network above, I believe you can also see the importance of instrumentation in many industries. If you have just joined the instrumentation industry, this is your first choice.

Nitrogen Compressor is one Gas Compressor used to increase nitrogen pressure. Normal nitrogen pressure at the outlet of Nitrogen Generator is  5-10 bars. For some customers, they need high puressure nitrogen such as 30 bars or 150 bars or 200 bars. Piston nitrogen compressor is the most popular type.

Oil Free Piston Nitrogen Compressor

Nitrogen compressor specifications:

Code

Item

Unit

Specification

1

Model No.

 

VW-45/6-32

2

Structure

 

Two stage, skid mounting

3

Medium

 

Nitrogen

4

Rated suction pressure

MPa(g)

0.6

5

Rated outlet pressure

MPa(g)

3.2

6

Capacity

Nm3/h

45@ suction pressure=0.6MPa(g)

7

Rotation speed

rpm

680                   â€»

8

Motor power

kw

5.5                    â€»

9

Cooling type

 

Wind cooling

10

Drive type

 

Belt

11

Inlet temperature

℃

≤35

12

Outlet temperature

℃

≤55

13

Inlet joint

 

DN25

14

Outlet joint

 

DN15

15

Control

 

Automatic

16

Weight

KG

360                   â€»

17

Dimension(length*width*height)

mm

1200*900*950          â€»

18

Installation

 

Flat concrete ground

Nitrogen Compressor

Nitrogen Compressor,Oilless Nitrogen Compressor,Nitrogen Air Compressor,High Pressure Nitrogen Compressor

Shandong Gamma Gas Engineering Co. Ltd. , http://www.gammagas.com