1. Mini-pleat design, operational cost saving
2. Wide application, compact design, space-saving
3. Ultra-thin design, installation space-saving
4. Efficiency:99.95%@MPPS(H13)
           99.995%@MPPS(H14)
Applications: Â Applicable to clean room and other area with stringent clean air requirements
Applicable conditions:  Working  temperature(ºC)   ≤ 70(158ºF)
Product DetailsÂ
Type:   Mini-pleat HEPA filter                   Gasket: CR,EVA,EPDM,PUÂ
                    Â
Frame:Â Extruded aluminum. Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Face guard: Â Baking finish
Separator: Hot-melt beads. Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Filter class(EN1822):H12, H13,H14
Media:Â H&V Glass fiber, Â PTFE Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Recommended final pressure drop.: Â 500 Pa.
Temperature / Humidity: 70°C / 100% RH    Â
Pictures
Workshop Show
Production Process
Standard Size
We not only produce all kinds of different normal size Mini-pleat HEPA filter,but also accept all kinds of customized
size Mini-pleat HEPA filter.Please choose what size you want to buy refer to the below table,
Model Dimensions (W×H×D) mm  |
Filter grade EN1822  |
Airflow / pressure drop m³/h / Pa (± 15%)  |
Unit volume m³ |
610x610x50 | H13 | 603/130 | 0.041 |
1170X1170X50 | H13 | 2218/125 | 0.082 |
1170x570x50 | H13 | 1080/130 | 0.073 |
610x610x70 | H13 | 603/110 | 0.026 |
1170X1170X70 | H13 | 2218/105 | 0.052 |
1170x570x70 | H13 | 1080/110 | 0.046 |
610x610x90 | H13 | 603/85 | 0.033 |
1170X1170X90 | H13 | 2218/80 | 0.066 |
1170x570x90 | H13 | 1080/85 | 0.060 |
610x610x50 | H14 | 603/140 | 0.041 |
1170X1170X50 | H14 | 2218/135 | 0.082 |
1170x570x50 | H14 | 1080/140 | 0.073 |
610x610x70 | H14 | 603/120 | 0.026 |
1170X1170X70 | H14 | 2218/115 | 0.052 |
1170x570x70 | H14 | 1080/120 | 0.046 |
610x610x90 | H14 | 603/95 | 0.033 |
1170X1170X90 | H14 | 2218/90 | 0.066 |
1170x570x90 | H14 | 1080/95 | 0.060 |
Packing and Shipping
FAQ
Q1. Are you a manufacturer?
Yes, we are a high-tech enterprise which with 20 years experience in developing and manufacturing various filters and purification equipments.
Q2. What is your terms of packing?
A: Generally, we pack our goods in neutral white boxes and brown cartons. If you have legally registered patent, we can pack the goods in your
branded boxes after getting your authorization letters.
Q3. What is your terms of delivery?
A: EXW, FOB, CFR, CIF, DDU.
Q4. How about your delivery time?
A: Generally, it will take 7 to 15 days after receiving your advance payment. The specific delivery time depends on the items and the quantity of
your order.
Q5. Can you produce according to the samples?
A: Yes, we can produce by your samples or technical drawings. We can build the molds and fixtures.
Q6. What is your sample policy?
A: We can supply the sample if we have ready parts in stock, but the customers have to pay the sample cost and the courier cost.
Q7. Do you test all your goods before delivery?
A: Yes, we have 100% rigorous test before delivery.
Q8.What is your terms of payment?
A: T/T 30% as deposit, and 70% before delivery. We'll show you the photos of the products and packages before you pay the balance.
Q9.How do you make our business long-term and good relationship?
A:1. We keep good quality and competitive price to ensure our customers benefit ;
2. We respect every customer as our friend and we sincerely do business and make friends with them, no matter where they come from.
                Welcome To Visit Our Factory!
Â
Fan Coil
Fan coil unit as terminals of Central Air Conditioner. Equipped with main air cooled chiller or Water Cooled Chiller to cool or heat the target place.
Characteristics:
1.Durable construction. Casing of Lark fan coil units shall be galvanized steel panel. And the condensate pan is treated by extruded seamless technology to prevent the leakage. Fire rated thermal insulation is attached to the condensate pan
integrally. Construction of the units is sturdy and permanent.
2.High efficiency. Coils shall be fabricated by Φ9.25mm cooper tubes and hydrophilic aluminum fins. Tubes are expanded
into the fins accurately to confirm the heat transfer efficiency. Fans shall be high airflow rate and low noise
design. And brass headers of copper tubes well distribute water flow configuration to assure optimum heat
transfer efficiency.
3.Low noise and operating cost. Fans shall be specially designed with over-sized galvanized multi-blade centrifugal wheel, operating with low noise, high static pressure and airflow rate. And hi-static, permanent split capacitor motors shall be factory
balance tested for proof the high efficiency and quite operation.
4.Easy maintenance. Motors shall be fabricated with rolling bearing and quenched and tempered steel shaft with antirust treated. Three-speed or LCD thermostat is convenient to control the airflow and room temperature.
5. Low installation cost. Units shall be low-weight design. Drain pipes and wires are easy for connection. The water connection direction and air return are changeable according to the site requirements.
1. Exposed Fan Coil unit
Air flow: 340m3/h-2380m3/h, Cooling capacity: 1800W-12600W
2.Concealed Fan Coil Unit
Air flow: 340m3/h-2380m3/h, Cooling capacity: 1800W-12600W
3. Cassette Fan Coil
Air flow: 340m3/h-2380m3/h, Cooling capacity: 2000W-12800W
4.Wall Mounted Fan Coil
Air flow: 340m3/h-1360m3/h, Cooling capacity: 1808W-7210W
5.Chilled Water Fan Coil
Air flow: 340m3/h-2380m3/h, Cooling capacity: 1800W-12600W
6. Ducted Fan Coil
Air flow: 340m3/h-2380m3/h, Cooling capacity: 1800W-12600W
Fan Coil
Fan Coil,Fan Coil Radiators,Concealed Fan Coil,Chilled Fan Coil